ndminclogo.jpg (1705 bytes)

address.gif (1567 bytes)

phone.gif (1877 bytes)

               

 
 

7270 Basic Systems

6 Slot AC System

Part#

Description

Notes
90-4441-01 6 SLOT AC SYSTEM  
90-4443-01  UNIVERSAL AC P SUPPLY Need one power supply for each 3 slots and one additional for redundancy.
90-4452-31      7270 CONTROL CARD R4.3 Need additional unit for redundancy. Other options available depending on application
90-4453-03    HUB CARD -6*8 SLOT SYSTEMS Need additional unit for redundancy
90-6459-01    STRATUM 3 SSU MODULE Need additional unit for redundancy
90-4464-01      ALARM I/O CARD Optional
90-4451-03      1.S44M REF CLOCK IN Optional, International versions also exist
90-4521-13    7270  R4.3 TECHNICAL PRACTICES  
8 Slot AC System
90-4441 -02 8 SLOT AC SYSTEM  
90-4443-01 UNIVERSAL AC P.SUPPLY
Need one power supply for each 3 slots and one additional for redundancy.
90-4452-31     7270 CONTROL CARD H4.3
Need additional unit for redundancy. Other options availableds pending on application
90-4453-03    HUB CARD - 6 & B SLOT SYSTEMS Need additional unit tor redundancy.
90-6499-01      STRATUM 3 SSU MODULE Need additional unit tor redundancy.
90-4464-01    ALARM I/O CARD Optional
90-4451-03      1.544M REF CLOCK IN Optional, International versions also exist
90-4521-43    727OR4.3 TECHNICAL PRACTICES  
6 Slot DC System
90-4442-01 6 SLOT DC SYSTEM  
90-4444-01        48V DC POWER SUPPLY Need one power supply for each 3 slots and one additional for redundancy.
90-4452-31      7270 CONTROL CARD R4.3 Need additional unit for redundancy. Other options availableds pending on application
90-4453-03    HUB CARD- 6 & 8SLOTSYSTEMS Need additional unit tor redundancy.
90-6499-01      STRATUM 3 SSU MODULE Need additional unit tor redundancy.
90-1464-01      ALARM I/O CARD Optional
90-4451 -03      1.544M REF CLOCK IN Optional, International versions also exist
90-1521-43    7270 R4 3TECHNICAL PRACTICES  
8 Slot DC System
9O-4442-01        8 SLOT DC SYSTEM  
9O-4444-02        48V DC POWER SUPPLY Need one power supply for each 3 slots and one additional for redundancy.
90-4452-31      7270 CONTROL CARD R4.3 Need additional unit for redundancy. Other options availableds pending on application
90-4453-03      HUB CARD - 6 S B SLOT SYSTEMS Need additional unit tor redundancy.
90-6499-01      STRATUM 3 SSU MODULE Need additional unit tor redundancy.
90-1464-01      ALARM I/O CARD Optional
90-1451-03      1.544M REF CLOCK IN Optional, International versions also exist
90-1521-43      7270 R4.3 TECHNICAL PRACTICES  
Universal Card Slot Interface Maximum of 7 per 8 Slot System & 5 per 6 slot system)
(Control Redundancy reduces the slot count by one slot)
Cell Relay Interfaces
90-4456-02        0C3-2M CR CARD R4.3 Requires one of the OC3/STMI I/O cards below
90-4457-02        STM1-2M CR CARD R4.3 Requires one of the OC3/STMI I/O cards below
90-4462-01      0C3/STM1 SR I/O CARD  
90-4462-02    OC3/STM1 IR I/O CARD  
90-4462-03    OC3/STM1 LR I/O CARD  
90-4462-04    0C3/STM1 XLR I/O CARD  
90-4462-05    0C3/STM1 UTP5 I/O CARD  
90-4462-06    0C3/STM1CMIBNCI/0  
90-4462-07    OC3/STM1 CM1T43 I/O  
90-4458-05        DS3 3 PORT CR CARD W/CPU-2(t35K) P.4.3 Requires the DS3/E3 I/O card shown below
90-4458-06        E3 3 PORT CR CARD WCPU-2 (13.SK) R4.3 Requires the DS3/E3 I/O card shown below
90-4458-13        DS3 3 PORTCH CARD W/CFU-2 R4.3 Requires the DS3/E3 I/O card shown below
90-4458-14       E3 3 PORT CR CARD W/CPU-2 R4 3 Requires the DS3/E3 I/O card shown below
9O-4463-01     DS3/E3 3P BNC I/O CARD  
90-4463-02    DS3/E3 3P T43 I/O CARD  
90-4459-23      T1 8 PORT CR CARD W/CPU-2 R4.3 Requires one of the T1 I/O cards shown below
90-4459-24      E1 8 PORT CR CARD W/CPU-2 R4.3 Requires one of the T1 I/O cards shown below
90-4460-01    T1 8 PORT I/O CARD  
90-4460-02    E1 8PORT 120 OHM I/O CARD  
90-4460-03    E1 8PORT75OHMBNC I/O  
90-4460-04    E1 8P 75 0HM TYPE43 I/O  
90-6743-01        IMA MODULE FOR T1/EI CR Optional for IMA support on T1/E1 CR cards above.
90-4724-01        M/5 TRAFFIC SHAPING MDL Optional for IMA support on T1/E1 CR cards above.
90-6744-02        HIGH SPEED MTSM
Optional for Traffic shaping on DS3/E3, OC3/STM1 cards
above.
90-7695-01 eTM module R4.3
Optional for Traffic shaping on all cards above. Includesadditional functions to those supported by the other traffic
shaping modules above.
Voice Service Interfaces
90-4653-01        T1 4 PORT VOICE BAND VSC Requires one of the T1 I/O Cards shown below
90-4653-02        E1 4 PORT VOICE BAND VSC Requires one of the T1 I/O Cards shown below
90-4461-01     T1 4PORT I/O CARD  
90-4461-02    E1 4PORT 120 OHM I/O  
90-4461-03    E1 4PORT 75OHM BNC I/O  
90-4461-04    E1 4P 750HM TYPE 43 I/O  
90-4654-01        VS DSP1 TRANSPORT MODULE One DSP for 40 compressed voice channels (3 per card). Supports G711.G726.
90-4654-02      VS DSP1 TRANSPORT MODULE with G.729 A One DSP for 40 compressed voice channels (3 per card). Supports G711.G726.
Frame Relay Interfaces
90-4454-11        T1 4 PORT CFR CARD R4.2 Requires one of the T1 I/O Cards shown below
90-1454-12        E1 4 PORT CFR CARD R4.2 Requires one of the T1 I/O Cards shown below
90-4461-01    T1 4PORT I/O CARD  
90-4461-02    E1 4PORT 120OHM I/O  
90-4461-03    E1 4PORT 7SOHM BNC I/O  
90-4461-04    E1 4P 75OHM TYPE 43 I/O  
90-8828-11        PSI 16 P0RT FR CARD R4.3 Requires the I/O Card below
90-6388-01        PSI 16 P0RT FR CARD R4.3  
Circuit Emulation Interfaces
90-4456-21        T1 8 PORT CE CARD R4 3 Requires one of the I/O cards shown below
90-4456-22       61 8 PORT CE CAPD R4.3 Requires one of the I/O cards shown below
90-4460-01    T1 8PORT I/O CARD  
90-4450-02    E1 8PORT 120 OHM I/O CARD  
90-4460-03    E1 8 PORT 75 OHM BNC I/O  
90-4460-04    E1 8P 75 OHM TYPE 43 I/0  
90-6627-11        DS3 CES SINGLE PORT R4.2 Requires the DS3 I/O card shown below
90-4463-04         DSE/E3 IP BNC I/O CARD  
90-7285-01        ECHO CANCEL MOD FOR PRI CE-63MS Optional for the T1/E1 CE cards above
90-7285-02        ECHO CANCEL MOD FOR PRI CE-127MS Optional for the T1/E1 CE cards above
90-7116-01        LICENSE ISDN PRI T1/EI  
Ethernet Interfaces
90-6602-21        10/100 MB ETHERNET CARD R4.3 Requires one of the I/O cards shown below
90-6603-01        E-NET4P10/100BASE-T I/O  
90-7104-02        E-NET4P 100 BASE-FX MMF I/O  
90-7104-04        E-NET4P 100 BASE-FX SMF I/O  
IP Service Interfaces
90-8016-11 IP services Card (ISC) R4.3
 
 

Required if IP Routing & other services are necessary

Cables
90-6502-01        DCE CABLE 3NU1ALE V.28 Required for the interface type desired for each port of the FR PSI card above
9O-6502-02        DTE CABLE SM/U/ieV 28  
90-6502-03        DTĄ CABLE 3M/FEMALE V.28  
90-6502-04        DCE CABLE 3M/F6MALE V.28  
90-7004-01        DCE CABLE 3M/MALE X.21  
90-7004-02        DTE CABLE 3M/MALE X.21  
90-7004-03        DTE CABLE 3M/FEMALE X21  
90-7CO4-04        DCE CABLE 3M/FEMALE X21  
90-7005-01        DCE CABLE 3M/MALE V.35  
90-7005-O2        DTE CABLE 3M/MALE V.35  
90-7005-03        DTE CABLE 3H/FEMALE V.35  
90-7005-04        DCE CABLE 3M/ FEMALE V.35  
Miscellaneous
90-4449-01        7270 SPARE 6&8 SLOT BLANK UCS CARD One required per empty card slot
90-6894-43        7570 R4.3 S/W CD  

GO TO OUR HOMEPAGE - CLICK

You've come to the right place for High quality,

Newbridge products!

 

 

 

NationalDataMux 2002. - All products, logo's and brand names mentioned are trademarks or registered trademarks of their respective owners.