Modular Console Server, Alarm
Management |
|
Terminal Server Modules |
|
Model # |
Description |
|
N9-000-723 |
Access
Server I/O module, 20 ports via RJ-45 connectors. Supports
concurrent hardware modem control and hardware flow
control. |
|
N9-000-724 |
Access
Server I/O module, 24 ports via three Telco connectors. |
|
N9-720-000-4 |
Access
Server processor module, 4 MB RAM. |
|
N9-720-000-6 |
Access
Server processor, 6 MB RAM. |
|
Ethernet Management
Processor Modules |
|
N9-210-000 |
Management
processor module. |
|
Ethernet Concentrator I/O
Modules |
|
N9-000-203A |
20-port
10Base-T Enhanced I/O module. Integrated RJ-45
connectors. |
|
Accessories |
|
NETWORK 9000: Chassis-Based
Solutions |
|
Chassis |
|
N9-9006-021 |
6-slot
chassis including AC controller module and cooling fans.
Requires AC power supply. |
|
N9-9106-021 |
6-slot
chassis with SwitchPlane including AC controller module and
cooling fans. Requires AC power supply. |
|
N9-9115-021 |
15-slot
chassis with SwitchPlane including AC controller module and
cooling fans. Requires AC power supply. |
|
N9-9106-022 |
6-slot
chassis with SwitchPlane including DC controller module and
cooling fans. Requires DC power supply. |
|
N9-9006-022 |
6-slot
chassis including DC controller module and cooling fans.
Requires DC power supply. |
|
N9-9115-022 |
15-slot
chassis with SwitchPlane including 2 redundant AC controller
modules. Requires AC power supply. |
|
N9-9115-023 |
15-slot
chassis with SwitchPlane including DC controller module and
cooling fans. Requires DC power supply. |
|
N9-9115-024 |
15-slot
chassis with SwitchPlane including 2 redundant DC controller
modules. Requires DC power supply. |
|
Power Supplies |
|
N9-020-119 |
Spare AC
controller module. |
|
N9-020-119D |
Spare
48-Volt DC controller module. |
|
N9-020-119DR |
Spare
redundant DC controller module. For use with N9-9015 or
N9-9115 only. Customer must provide the Ethernet address for
the redundant module at the time the order is placed. |
|
N9-020-119R |
Spare
redundant AC controller module.For use with N9-9015 or N9-9115
only. Customer must provide the Ethernet address for the
redundant module at the time the order is placed. |
|
N9-125-020 |
Unmanaged
AC power supply. |
|
N9-130-020 |
Managed AC
power supply. |
|
N9-150-020 |
Managed DC
power supply. |
|
Cables and
Adapters |
|
MX-151-3039 |
V.35 cable,
male 34 pin to male 35 pin. 15 feet. |
|
MX-151-3148 |
V.35 male
to V.35 male cable, 15 feet. Supports RING on V.35 pin
L. |
|
MX-350-0369 |
UTP
Category 5 cable with RJ-45 connectors, straight-through
cable. Use with 10 Mbps-155 Mbps applications, including
10Base-T, 100Base-T, TP-PMD and ATM. 10 feet. |
|
Miscellaneous |
|
N9-000-003 |
Cable
management ears, 6-slot chassis. |
|
N9-000-004 |
Cable
management ears, 15-slot chassis. |
|
N9-000-006 |
Blank
panel, front, 1-slot. |
|
N9-000-007 |
Blank
panel, rear, 1-slot. |
|
N9-000-106 |
Spare fan
module. |
|
Upgrades |
|
Memory
Upgrades |
|
N9-500-8183 |
4 MB SIMM
field upgrade for 401 and 402 processor modules. |
|
Flash Cards |
|
MX-440-0287 |
4 MB Wrap
Series 2 Flash Card. No software |
|
Internetworking
& Media Products Software Kits |
|
MED-IM-08 |
Flash
memory card, 4MB, for 401/4xx Router. Branch image only. |
|
MED-IM-10 |
Flash
memory card, 4MB, for Ethernet Management Processor. |
|
MED-IM-11 |
CD-ROM kit.
Master product software kit.Includes all internetworking and
media software and documentation. |
|
MED-IM-16 |
Flash
memory card, 4 MB, for the 401/4xx router and 210/211
Management Processor. Branch image only. |
|
MED-IM-19 |
4-MB flash
memory card for the Network 3000 with regional image including
IP, IPX, AppleTalk, Frame Relay, PPP, Spanning Tree Bridging,
ISDN, DECnet. Requires 8 MB of main memory; for Network 3000
only, not compatible with ROUTERUNNER products. |
|
MED-IM-20 |
Flash
memory card, 4 MB, for the Network 9000 with regional
image. |
|
MED-IM-21 |
Flash
memory card, 4 MB, for the Network 9000 with enterprise
image. |
|
Frame Relay
Software |
|
MX-420-0617 |
Frame Relay
Option. User-installable software key to enable Frame Relay
interface on Bridge/Router products.Not required on the
Network 3000 and ROUTERUNNER products. |
|
X.25
Software |
|
MX-420-0824 |
X.25 Router
Link Option. User-Installable software key to enable X.25 as a
Bridge/Router link option on all bridge/router products except
the Network 3000. Router should have at least 5 MB of
memory. |