Products
Embedded Device Servers
Device Servers
Embedded Software
Terminal Servers
Console Servers
ETS16PR & ETS32PR
SystemConsoleSwitch
SCS100/200/400
SCS1600 & SCS3200
SCS820 & SCS1620
CS3200/SCS3230
SCS3205/SCS4805
Console Management Software
Server Management
Visualization
Print Servers
Network Time Servers

Specifications
Ordering

Remotely monitor and manage network and telecom
equipment over IP networks or through a modem
Serial interface supports RS-232, RS-422, and RS-485 devices (see product specifications)
Secure Shell (SSH) access provides strong authentication
and secure communications
In-Band management offers convenient access over IP
networks
Modem support for Out-of-Band management (SCS200/400)
Type I/II PC Card interfce supports wireless adapters, storage cards, analog and cellular modems (SCS200/400)
Event logging and e-mail notification accelerates
troubleshooting
Configurable menus allow quick and direct access to
equipment
Easy setup and configuration using included EZWebCon™
Management Software
No inadvertent breaks - Solaris Ready

Lantronix Secure Console Servers provide unlimited access to remote network and telecom equipment, helping you maintain optimum system performance and availability.

Using your existing IP network or a single modem connection, Secure Console Servers provide remote access to data and voice equipment. All that is required is an available console or serial port (RS-232, RS-422, RS-485) on your equipment. Secure Console Servers are a flexible and powerful tool to manage devices such as: hubs, switches, routers, servers, UPS systems, PBX systems, and telecom switches.

Using In-Band management, you can manage your equipment over the network, from virtually any place you have access, using familiar tools like Telnet or Secure Shell (SSH).

Even if the network is down, Secure Console Servers have an Out-of-Band management feature that allows dial-in access through a modem connection. Where multiple pieces of equipment are installed, modem sharing allows you to realize a significant savings in installation and monthly operating costs.

Secure Console Servers ensure the integrity of your equipment and data through several measures. Authentication limits access to authorized users only, using usernames and passwords, modem dial-back, PAP/CHAP, Radius, Kerberos and SecurID. Authorization restricts access to equipment and services, based on stored user profiles. Secure Shell (SSH) safeguards login passwords and in-transit data through strong encryption.

Managing remote equipment can be a challenge, especially when system configurations vary from location to location. For quick and direct access to your equipment, Lantronix Secure Console Servers feature a configurable menuing system. This system allows remote equipment to be selected using your own descriptions. For example, menus could be organized by equipment location and name. Menus can also be configured specifically for each user, limiting access to specific equipment.

Event management features help you locate the source of equipment problems and diagnose them quickly. Each serial port can be independently configured to store console messages from attached equipment, and to alert a network manager of a potential problem by e-mail over the network or through an alternate modem connection. Upon receiving notification, network managers can review the stored console messages to determine the cause of the problem.

Secure Console Servers are available with 1 (SCS100), 2 (SCS200) or 4 (SCS400) high-speed serial ports and a 10/100 Mbps (10Base-T, 100Base-TX) Ethernet interface.s. Setup can be accomplished through a serial port, by using Telnet or with the included cross-platform EZWebCon™ configuration utility.

When you need to remotely monitor and manage your network and telecom equipment, look to Lantronix for a complete Console Management Solution - connecting you with your information.

 

Supported Protocols

IP, TCP/IP, UDP/IP, ARP, RARP, ICMP,
SNMP, BOOTP, DNS, WINS, RIP, Static Routing, PPP, TFTP, FTP, Telnet, rlogin, HTTP, and SLIP

Network Interface Ethernet 10Base-T or 100Base-TX RJ45
Serial Interface

SCS100
1 RS-232 connector (DB25 male, DTE)

SCS200
1 RS-232, RS-422/485 connector (DB25 male, DTE), 1 RS-232 (DB9 male, DTE) connector

SCS400
4 RS-232 connectors (DB9 male, DTE)

Serial Speeds 300bps to 230Kbps
PC Card Interface SCS200/400
Type I/II PC Card interface supporting wireless, modems, and storage cards
Click here for a list of currently supported PC Cards 
Modem Control RTS, CTS, DSR, DCD, DTR
Flow Control XON/XOFF or hardware flow control
Security

Secure Shell (SSH)

Authentication: Username/Passwords, modem dial-back, PAP/CHAP, Radius, Kerberos, and SecurID

Authorization: group and user menus, rules-based IP packet filtering, configurable date and time access restrictions

Port Logging Buffer size: 250 kBytes/port
Event Email notification
Management

SNMP, serial login, Telnet, rlogin, built-in web server (HTTP), and EZWebCon™ Java-based setup utility

Firmware Flash ROM Standard, downloadable from a TCP/IP host using TFTP, or EZWebCon™
Diagnostic LEDs

Power: Power applied
Link: Connected to the network
100: 100Base-TX connection
OK: Network activity / fault code
Serial: Serial activity (SCS100/200)
Serial 1 to Serial 4: Serial activity (SCS400)
PC Card: PC card activity (SCS200)
PCC1 and PCC2: PC card activity (SCS400)

Compatibility Ethernet Version 2.0/IEEE 802.3
Power Requirements

SCS100
Input: 5 VDC
Consumption:0.7A max. (AC adapter included)

SCS200
Input: 7-24 VDC
Consumption: 0.8A max. (100-240 VAC adapter included)

SCS400
Input: 9-30 VDC
Consumption: 1.84A max. at 12 VDC (AC adapter included)

Environmental

Operating Temperature:
5 to 50°C (41 to 122°F)

Storage Temperature:
-40 to 66°C (-40 to 151°F)

Physical Dimensions
(HxWxD)
SCS100
0.9 x 2.5 x 3.5 in
(2.3 x 6.4 x 9.0 cm)
Weight 0.8 lbs (0.35 kg)

SCS200
1.0 x 5.75 x 7.0 in
(2.5 x 14.6 x 17.8 cm)
Weight 1.3 lbs (0.58kg)

SCS400
1.3 x 9.3 x 5.5 in
(3.3 x 23.6 x 13.9 cm)
Weight 1.13 lbs (0.51kg)

Shipping
Dimensions
(HxWxD)
SCS100
4.5 x 9.5 x 7.5 in
(11.5 x 24.2 x 19.1 cm)
Weight 3.0 lbs (1.5 kg)

SCS200
2.75 x 13.25 x 6.75 in
(7.0 x 33.7 x 17.1 cm)
Weight 3.6 lbs (1.63kg)

SCS400
5.5 x 11.0 x 8.25 in
(13.9 x 27.9 x 20.9 cm)
Weight 3.6 lbs (1.63kg)

Agency Approvals FCC (A), C/UL, TUV, CE (B)
Warranty 1-year limited warranty - as of August 1st, 2003

Part Number Description
SCS100-01 Secure Console Server with RS-232 (DB25 Male) serial interface, 10Base-T/100Base-TX Ethernet interface (RJ45), diagnostic LEDs, CD-ROM with configurable tools and documentation, printed Quick Start Guide, and 115 VAC 50/60 Hz power adapter
SCS100-02 Same as above, but with 100-240 VAC 50/60 Hz International power adapter
SCS200 Secure Console Server with 1 DB25, RS232/RS422/RS485 serial port and 1 DB9 Male RS232 serial port interface, Full modem control; 10BaseT/100Base-TX Ethernet Interface (RJ45); Routes IP protocols; Type I/II PC Card; CD-ROM with EZWebCon™, port redirection software and reference manual; Installation guide; External 100-240 VAC Adapter
SCS400-01 Secure Console Server with four (4) RS-232 (DB9 Male) serial ports, 10Base-T/100Base-TX Ethernet interface (RJ45), dual PCMCIA interface (2 typei/II or 1 type III), diagnostic LEDs, CD-ROM with configurable tools and documentation, printed Quick Start Guide, and 115 VAC 50/60 Hz power adapter
SCS400-02 Same as above, but with 100-240 VAC 50/60 Hz International power adapter
SCS100 Datasheet (PDF)
SCS200 Datasheet (PDF)
SCS400 Datasheet (PDF)
SCS100/200/400 Quick Start Guide (PDF)
French Quick Start (PDF)
German Quick Start (PDF)
Italian Quick Start (PDF)
Spanish Quick Start (PDF)
SCS100/200/400 User Guide (PDF)
French User Guide (PDF)
German User Guide (PDF)
Italian User Guide (PDF)
Spanish User Guide (PDF)
Secure Console Server Reference Manual (PDF)
List of Supported PC Cards
Latest Firmware
Networking Tutorials
Glossary
 

 

 

Back to Home Page

                                      

                         

 

©National Data Mux 2002. - All products and brand names mentioned are trademarks or registered trademarks of their respective owners