INTEGRATED ACCESS |
|
Total Access 1500
Units |
|
Model # |
Part # |
Description |
|
Total Access 1500 23" Chassis |
1180001L1 |
Flush-mount or mid-mount in rack. Dual -48
VDC power feeds. Supports up to four T1 s plus a protect T1 for network
access. Supports up to 96 2-wire subscriber circuits. Provides PTGC
interlace for MLT capability. |
|
Total Access 1500 Heat Baffle |
1180002L1 |
Total Access 1500 Heat Baffle. |
|
Total Access 1500 Test Access Unit |
1180006L1 |
Converts -48 VDC for all cards in system;
Two PSUs provide redundancy for system; |
|
Total Access 1500 Power Supply Unit (PSU)
w/Ring Generator |
1180007L1 |
Converts -48 VDC for all cards in system.
Two PSUs provide redundancy for system. 20 REN ring generator. |
|
Total Access 1500 Power Supply Unit |
1180007L2 |
Converts -48 VDC for all cards in system.
Two PSUs provide redundancy for system. |
|
Total Access 1500 System Control Unit (SCU) |
1180008L1 |
System Control Unit for Total Access 1500.
Provision shelf using Telnet or Craft Interface. Management using TL1 or
SNMP. Supports Metallic Loop Testing (MLT). |
|
Total Access 1500 SCU COT w/MLT |
1180008L2 |
System Control Unit for Total Access 1500.
Provision shelf using Telnet or Craft Interface. Management using TL1 or
SNMP. Central office terminal that supports Metallic Loop Testing (MLT). |
|
Total Access 1500 SCU RT w/MLT |
1180008L3 |
System Control Unit for Total Access 1500.
Provision shelf using Telnet or CraftInterface. Management using TL1 or
SNMP. Remote terminal unit that supportsMetallic Loop Testing (MLT). |
|
Total Access Dual T1 Line Interface Unit
(LIU). |
1180009L1 |
Line interface unit for Total Access 1500.
Supports both POTS and Specials. Two LIUs provide protection switching
for the system. Supports TR-008 signaling. Four T1 version available
that offers an additional protect T1 for SLC 96 operation. |
|
Total Access 1500 LIU Blank Plug |
1180010L1 |
Blank for LIU slot in the Total Access 1500
Chassis (1180001L1}. |
|
Cable Assembly, 4x50 Pinto 100-Pair, 100' |
1180011L100 |
4X50 Pin to 100-Pair. 100 feet long. |
|
Cable Assembly, 4x50 Pinto 100-Pair, 200' |
1180011L200 |
4X50 Pin to 100-Pair. 200 feet long. |
|
Cable Assembly, 4x50 Pinto 100-Pair, 25' |
1180011L25 |
4x50 Pin to 100-Pair. 25 feet long. |
|
Cable Assembly, 4x50 Pinto 100-Pair, 300' |
1180011L300 |
4X50 Pin TO 100-Pair. 300 feet long. |
|
Cable Assembly, 4x50 Pinto 100-Pair, 50' |
1180011L50 |
4x50 Pin to 100-Pair. 50 feet long. |
|
Total Access 1500 Power Supply/Battery
Charger |
1180043L1 |
AC power for a fully loaded Total Access 1500
bank (96 FXS) while fully charging the battery backup system within 48
hours. All mounting hardware included. Built-in fuse. Multi-feature
status LED. Modular connections. Positive ground. Uninterrupted power
output if battery backup connected. FCC and UL 1950 compliant. |
|
Total Access 1500 Wall Mount Brackets |
1180046L1 |
Total Access 1500 wallmount bracket. |
|
Total Access 1500 Quad TI + Protect T1 LIU |
1180109L1 |
Line interface unit for Total Access 1500.
Offers an additional protect T1 for SLC 96 operation. Supports both POTS
and Specials. Two LIUs provide protection switching for the system.
Supports TR-008 signaling. Version available to support one and two
T1s(1180009L1). |
|
35' DB26/V.35 Adapter Cable |
1200167L135 |
35 ft. DB26 to V.35 adapter cable for
1180025L1. |
|
Total Access 1500, 2 PSU / Ring Generator,
4+P LIU, RT SCU 1 Quad RPOTS |
4180001L0 |
Includes: 1 - 1180001L1, 2 - 1180007L1
(PSU/RG), 1 -1180408L1L1 (QUAD FXS/R-POTS),1 -1180008L3(RT SCU)
configurable. |
|
Total Access 1500 Chassis, 2 L1 PSU, Quad
LIU |
4180001L1 |
Includes; 1 -1180001L1, 2 - 1180007L1 (PSU/RG),
1 -1180109L1 (Quad T1 LIU), 1 1180008L3 (RT SCU] configurable. |
|
Total Access 1500 RT, Quad LIU, 6 R-POTS |
4180001L6 |
Includes: 1 - 1180001L1, 2 - 1180007L1
(PSU/RG), 1 -1180109L1 (QuadTI LIU), 1 1180008L3 (RT SCU), 6 -1180408L1
(RPOTS) configurable. |
|
96 Line DLC Card Set, Redundant LIU |
4180101L1 |
96 Line DLC Card Set, Redundant Quad T1
LIUs. |
|
96 Line DLC Card Set, Non-Redundant LIU |
4180101L2 |
96 Line DLC Card Set, Non-Redundant Quad T1
LIUs. |
|
48 Line DLC Card Set, Non-Redundant LIU |
4180101L3 |
48 Line DLC Card Set, Non-Redundant Quad T1
LIUs. |
|
24 Line DLC Card Set, Non-Redundant LIU |
4180101L4 |
24 Line DLC Card Set, Non-Redundant Quad T1
LIUs. |
|
Total Access 1500, D4 CFG |
4180001L4 |
Includes: P/N 1180001L1 (1); P/N 1180007L2
(PSU) (1); P/N 1180008L1(SCU) (1); P/N 1180009L1 (DUAL LIU) (1). |
|
Total Access 1500, Redundant w/Cable |
4180001L2 |
Includes: P/N 1180001L1 Total Access 1500
23-in. Chassis (1); P/N 1180008L1 Total Access 1500 SCU (1); P/N
1180011L4 Total Access 1500 DLC Converter Cable (1); P/N 1180007L1 Total
Access 1500 PSU/RG (2); P/N 1180109L1 Total Access 1500 LIU 4T1+P (1). |
|
Total Access 1500 RT, Single Quad LIU, 24
RPOTS |
4180001L24 |
The system includes one Total Access 1500
23" chassis (1180001L1) and one 96 Line DLC card set, non-redundant
(4180101L2). |
|
96 Line DLC Card Set, Redundant LIU |
4180101L1 |
96 Line DLC Card Set, Redundant Quad T1
LIUs. |
|
96 Line DLC Card Set, Non-Redundant L |
4180101L2 |
96 Line DLC Card Set, Non-Redundant Quad T1
LIUs. |
|
48 Line DLC Card Set, Non-Redundant L |
4180101L3 |
48 Line DLC Card Set, Non-Redundant Quad T1
LIUs. |
|
24 Line DLC Card Set, Non-Redundant L |
4180101L4 |
24 Line DLC Card Set, Non-Redundant Quad T1
LIUs. |
|
Total Access 1500 PSU/RG, 19" |
1180007L3 |
Converts -48 VDC for all cards in Total
Access 1500 system and provides up to 20 REN ring generation. Two PSUs
provide redundancy and up to 40 REN for the system. Narrower design for
deployment in both 19" and 23". Total Acess 1500 Chassis. |
|
Total Access 1500 PSU, EXT RG, 19" |
1180007L4 |
Converts -48 VDC for all cards in Total
Access 1500 system. Two PSUs provide redundancy; designed to operate
with an external bulk ring generator source. Narrower design for
deployment in both 19" and 23". Total Acess 1500 Chassis. |
|
COT SCU, Test Access |
1180008L22 |
Total Access 1500 Central Office Terminal
System Control Unit with MLT controls all common equipment and access
modules. Supports VT100 local craft interface, TL1 over TCP/IP or X.25,
Telent, and SMNP. Includes Voice Frequency (VF) test access for turn-u |
|
RT SCU, Test Access |
1180008L23 |
Total Access 1500 Remote Terminal System
Control Unit with MLT controls all common equipment and access modules.
Supports VT100 local craft interface, TL1 over TCP/IP or X.25, Telent,
and SMNP. Includes Voice Frequency (VF) test access for turn-up and tr |
|
Total Access 1500 19" Chassis |
1180019L1 |
Flush-mount or mid-mount in rack. Dual -48
VDC power feeds. Supports up to four T1s plus a protect T1 for network
access; supports up to 72 2-wire subscriber circuits; provides a PTGC
interface for MLT capability. Uses sequential pinout for local loops. |
|
Total Access 1500 Powering U-BR1TE |
1180020L2 |
Provides span power for ISDN U-Repeater and
ISDL OSU-IP. Supports the transport of switched and non-switched ISDN
services over T1 facilities. |
|
Power Supply, Rackmount, PFC, 350W, 6A |
1180043L2 |
120 VAC to -54 VDC 6 AMP Power
Supply/Battery Charger. Built-in fuse, multi-feature status LED,
positive ground, and uninterrupted power output if battery backup
connected. Modular connections for up to two battery backup systems,
(1175044L1). Meets NEB |
|
Total Access 1500 Wall Mount Brackets |
1180046L1 |
Total Access 1500 wall mount bracket. |
|
Product Name Total Access 1500, 4T1+P, List
2 |
1180109L2 |
Product Description Total Access 1500 Quad
T1+ Protect T1 LIU w/Mode II and Fast Switchover. Supports POTS &
Specials in SLC (TR08) and D4 modes with Protect T1 in SLC modes I, II,
and III. |
|
Total Access 1500 TO, Single |
1180112L2 |
The Total Access 1500 4W TO is intended to
be deployed in the Total Access 1500 Chassis. The 4W TO provides a voice
grade 4wire analog interface between a VF transmission facility and the
Total Access 1500 backplane. The 4W TO generates no signaling |
|
ETO, Single |
1180113L2 |
Single Port 4-wire Equalized Transmission
Only (ETO). |
|
Total Access 1500 FXS/GT, Single |
1180114L2 |
The Total Access 1500 FXS/GT Access Module
is intended to be deployed in the Total Access 1500 Chassis. The FXS/GT
provides for a 2-wire analog interface between a Voice Frequency (VF)
transmission and signaling facility and the Total Access 1500 Pulse Co |
|
Total Access 1500 DX, Single |
1180116L2 |
The Total Access 1500 4W DX Access Module
is intended to be deployed in the Total Access 1500 Chassis. The 4W DX
provides for one 4-wire analog interface between a VF transmission and
signaling facility and the Total Access 1500 Pulse Code Modulation |
|
Total Access 1500 4W FXO, Single |
1180117L2 |
The Total Access 1500 4W FXO Access Module
is intended to be deployed in the Total Access 1500 Chassis. The 4W FXO
provides for one 4-wire analog interface between a VF transmission and
signaling facility and the Total Access 1500 Pulse Code Modulation |
|
Total Access 1500 4W FXS, Single |
1180118L2 |
The Total Access 1500 4W FXS Access Module
is intended to be deployed in the Total Access 1500 Chassis. The 4W FXS
provides for one individual 4-wire analog interface between a VF
transmission and signaling facility and the Total Access 1500 Pulse Code |
|
Total Access 1500 4-Wire Tandem |
1180119L2 |
GR-57 4W TDM access module for the Total
Access 1500 Chassis. The 4W TDM provides back-to-back connections of
carrier systems in a central office on services requiring loop-start or
ground-start signaling. |
|
Total Access 1500 TRI-C DP |
1180182L1 |
Total Reach ISDN Central Office DataPort
(TRI-C DP), TA 1500 form factor. Combines the functionality of a U-BR1TE
and a Total Reach ISDN central office unit. Extends ISDN to 30 kft using
ADTRAN SC PAM line code; derives data from T1. |
|
Total Access 1500 Dual ETO |
1180213L2 |
The Dual 4W ETO was designed for use in the
Total Access 1500 Chassis. The Dual 4W ETO provides two individual voice
grade 4wire analog interfaces between a VF transmission facility and the
Total Access 1500 backplane. |
|
Total Access 1500 Dual Coin RT |
1180433L1 |
The ADTRAN Dual Coin RT card is designed to
extend two coin circuits from the CO to a remote location. The card is
interoperable with a variety of 5E-class switches and GR-08CORE
compliant coin COT cards. Universal or Integrated digital loop carrier |
|
MULTIPRT SYNC/ASYNC Serial Module |
1180435L1 |
Single width TA 1500 module provides for
multiplexing up to 4 independent RS-232 ports over a single 64K DS0.
Supports synchronous and asynchronous operation. Requires Quad RS232
Adapter cable, 1180435L4 for customer interface. Operable with DSU III T |